Application
  The load cell PRE is an electrical transducer for the measurement of forces. It is mainly used to monitor anchor forces, in conventional and in prestressed structures (of any type). A load cell can also be used in other applications such as for anchor load testing, as well as lifting and load distribution on large containers.

For manual measurement the user friendly read-out unit Indipoc is used to display the load directly in kN. Due to its standard signal remote measurement is easily possible.A permanent load should not be more than 80% of the load cells nominal capacity (FS). For a short period the load cell may be loaded up to 110% of its nominal load without zero point shifting. The more rigid the supports (below and above of the load cell) the better the precision.
   
Description
  The load cell PRE is designed for the use on construction sites. Basically it is maintenance free, splashproof, temperature compensated and of robust mechanical design.

Strain gauges are applied in a temperature compensated arrangement directly on a thermically treated steel cylinder. When a load is applied, a change in resistance on the strain gauges results due to the deformation of the steel zylinder.The electrical signal is adjusted in order for the actual load to be read directly in kN on the read-out unit. Even eccentric loads can be monitored precisely due to the strain gauges arrangement.
   
 

Load cells PRE
   
Technical data
 
Type
PRE 1000/78/80
PRE 1000/100/80
PRE 1500/125/80
Nominal capacity (FS)
0 - 1000kN
0 - 1000kN
0 - 1500kN
Outside diameter
115mm
135mm
160mm
Bearing ring outside diameter
92mm
111mm
139mm
Bearing ring inside diameter*
78mm
100mm
125mm
Overall height
80mm
Measuring system
Strain gauges
Precision
1% FS
Temperature error
0.01%/°C
Resolution
1kN
Signal FS
3.3mV/V
Operating temperature
-30°C to +60°C
Overvoltage protection
optional
Cable
TS-PUR / TAP47
   
 
Type
PRE 2000/160/80
PRE 3000/190/80
PRE 10000/0/120
Nominal capacity (FS)
0 - 2000kN
0 - 3000kN
0 - 10000kN
Outside diameter
200mm
235mm
189mm
Bearing ring outside diameter
179mm
212mm
153mm
Bearing ring inside diameter*
160mm
190mm
without hole
Overall height
80mm
120mm
Measuring system
Strain gauges
Precision
1% FS
Temperature error
0.01%/°C
Resolution
1kN
10kN
Signal FS
2.12mV/V
3.3mV/V
Operating temperature
-30°C to +60°C
Overvoltage protection
optional
Cable
TS-PUR / TAP47
  *Center hole diameter
   
Downloads
 
Adobe Acrobat Dokument(*.pdf)